Error Code A044_F
High

Rheem R802VA07542117MSA Error Code A044_F: Inducer Lo Pressure Switch Won't Open

TL;DR
The Rheem R802VA low-stage inducer pressure switch is stuck closed when it should be open. The furnace cannot proceed with a safe startup sequence until a technician inspects and likely replaces the switch.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code A044_F Mean?

Fault code A044_F on the Rheem R802VA means the low-stage inducer pressure switch is remaining in the closed position when the inducer motor is off and the IFC expects it to be open. The pressure switch is a safety device that monitors the negative pressure created by the inducer draft motor in the flue passage. It should be open (no pressure) when the inducer is not running, and should close once the inducer builds sufficient draft.

When the switch is stuck closed before the inducer even starts, the IFC cannot confirm that the switch transitions correctly — which means it cannot verify proper draft creation during the pre-purge cycle. This prevents the furnace from attempting ignition safely.

Common causes include a mechanical failure inside the pressure switch itself (stuck diaphragm or welded contacts), a kinked or blocked sensing hose that maintains a small negative pressure at the switch even with the inducer off, or condensation buildup in the hose that creates a siphon effect.

Common Causes

Cause Likelihood DIY?
Pressure switch stuck in closed position Most common ✗ Call a pro →
Pressure switch hose blocked or kinked maintaining pressure Common ✗ Call a pro →
Defective pressure switch with welded contacts Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.