Error Code A115_F
High

Rheem R802VA07542117MSA Error Code A115_F: One-hour Lockout: Gas Valve Stuck Closed

TL;DR
The Rheem R802VA has entered a one-hour lockout because unexpected voltage was detected on the gas valve circuit. The furnace will attempt to restart automatically after the lockout, but a technician should inspect the gas valve and control board to prevent recurrence.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code A115_F Mean?

Fault code A115_F on the Rheem R802VA indicates a one-hour soft lockout triggered by detection of unexpected voltage on the gas valve circuit. Specifically, the IFC detects that voltage is present on the gas valve connections when the inducer motor has been shut off — a condition that should not occur under normal operation. After the one-hour lockout period, the furnace will attempt to restart automatically.

The gas valve circuit in the R802VA is controlled by a relay on the IFC board. Normally, voltage is only applied to the gas valve during an active heating cycle after all pre-ignition safety checks pass. Detecting voltage when the inducer is off can indicate either a defective gas valve that is generating back-voltage, a control board relay that is not fully releasing, or incorrect wiring that has connected voltage to the gas valve terminal at an unexpected time.

While this code produces a soft (self-clearing) lockout rather than a hard lockout, the root cause involves the gas valve circuit and should be investigated promptly. If the gas valve is stuck or partially energized when it should be off, there is a risk of uncontrolled gas flow.

Common Causes

Cause Likelihood DIY?
Defective gas valve not responding to electrical signal Most common ✗ Call a pro →
Wiring issue between control board and gas valve Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.