Error Code A126_F
High

Rheem R802VA07542117MSA Error Code A126_F: Flame not Sensed with Gas Valve On - UL

TL;DR
The Rheem R802VA gas valve is confirmed open but no flame is detected — a UL safety fault indicating possible unburned gas accumulation. Do not restart the furnace. Call a technician immediately.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code A126_F Mean?

Fault code A126_F on the Rheem R802VA is a UL (Underwriters Laboratories) safety fault that occurs when the IFC has confirmed the gas valve is energized and open, but the flame sensor is not detecting any flame. This is a critical safety condition because it means gas may be flowing into the furnace without being ignited.

During a normal ignition sequence, the IFC energizes the hot surface igniter, opens the gas valve, and then verifies flame presence within a few seconds via the flame sensor. If the valve is confirmed open (the relay has closed and voltage is applied) but flame is not detected, A126_F is set as a UL-level alarm. The UL designation means this fault is tied to the furnace's safety listing requirements.

Possible causes include a failed igniter that cannot heat to ignition temperature even though the gas valve has opened, a flame sensor that has completely failed and cannot detect flame even when the burners light momentarily, or a gas valve that is providing inadequate gas flow despite being electrically commanded open. In any of these cases, the risk of unburned gas in the furnace is present and the situation requires immediate professional attention.

Common Causes

Cause Likelihood DIY?
Failed igniter not producing spark or heat Most common ✗ Call a pro →
Failed flame sensor not detecting actual flame Common ✗ Call a pro →
Gas valve opening but insufficient gas flow Uncommon ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes