Rheem R802VA07542117MSA Furnace Error Codes

Two-Stage, Variable Speed Gas Furnace | Control Board: Bluetooth Communicating IFC

Not your model? View all Rheem models →

Disclaimer
This information is for reference purposes only and does not guarantee accuracy or completeness. Always consult your owner's manual and a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

All Error Codes

Code Name Severity DIY?
A001_F Model Data Configuration Error High ✗ Call a pro →
A002_F Blower Coefficient Configuration Error High ✗ Call a pro →
A011_F Failed Ignition High ✓ Yes →
T013_F Flame Lost after Established Low ✓ Yes →
A013_F Flame Lost after Established High ✓ Yes →
A014_F Flame Present with Gas Valve Off High ✗ Call a pro →
T022_F Main Limit Switch Open High ✓ Yes →
A022_F Main Limit Switch Open High ✓ Yes →
A031_F Open Fuse High ✗ Call a pro →
A033_F Roll-Out Switch Alarm High ✗ Call a pro →
A044_F Inducer Lo Pressure Switch Won't Open High ✗ Call a pro →
T045_F Inducer Lo Pressure Switch Won't Close High ✓ Yes →
T047_F Inducer Fan 5 Minute Lockout Low ✓ Yes →
A047_F Inducer Fan 5 Minute Lockout High ✓ Yes →
*T055_F Inducer Hi Pressure Switch Won't Open (Two-Stage Only) High ✗ Call a pro →
*A055_F Inducer Hi Pressure Switch Won't Open (Two-Stage Only) High ✗ Call a pro →
*T057_F Inducer Hi Pressure Switch Won't Close (Two-Stage Only) High ✓ Yes →
A061_F Blower Fault - Motor Cannot Run High ✗ Call a pro →
T081_F Return Air Sensor Fault Low ✗ Call a pro →
*T082_F Supply Air Sensor Fault (Two-Stage Only) Low ✗ Call a pro →
*T084_F Outdoor Air Sensor Fault (Two-Stage Only) Low ✗ Call a pro →
*T085_F Suction Line Temp Thermistor Failure (Two-Stage Only) Low ✗ Call a pro →
*T086_F Suction Pressure Sensor Failure (Two-Stage Only) Low ✗ Call a pro →
T087_F Power Board Temp Sensor Fault Low ✗ Call a pro →
*T088_F EXV Sensor Measurement Error (Two-Stage Only) Low ✗ Call a pro →
A093_F Internal Control Fault Detected High ✗ Call a pro →
A111_F One-hour Lockout: Main Limit Switch High ✓ Yes →
A113_F One-hour Lockout: Ignition Failure High ✓ Yes →
A114_F One-hour Lockout: Flame Lost Failure High ✓ Yes →
A115_F One-hour Lockout: Gas Valve Stuck Closed High ✗ Call a pro →
A116_F One-hour Lockout: Flame Presence Alarm High ✗ Call a pro →
T117_F Detect RPM Motor Failure Low ✗ Call a pro →
A117_F Detect RPM Motor Failure High ✗ Call a pro →
A126_F Flame not Sensed with Gas Valve On - UL High ✗ Call a pro →
A127_F Flame Present with Gas Valve Off - UL High ✗ Call a pro →
A221_F Configuration Data Restore Failure High ✗ Call a pro →
A222_F Model Data Restore Failure High ✗ Call a pro →
A223_F Internal Fault: Monitor Chip Comm Failure High ✗ Call a pro →
A224_F Flame Status Circuit Failure High ✗ Call a pro →
A225_F Internal Fault: Gas Valve 1 Relay Welded Shut High ✗ Call a pro →
A226_F Internal Fault: Gas Valve 1 Relay Stuck Open High ✗ Call a pro →
*A227_F Internal Fault: Gas Valve 2 Relay Welded Shut (Two-Stage Only) High ✗ Call a pro →
*A228_F Internal Fault: Gas Valve 2 Relay Stuck Open (Two-Stage Only) High ✗ Call a pro →
How to read these codes

A / T prefix. A code that starts with A is an Active fault — the problem is happening right now and the furnace has stopped or locked out. A code that starts with T is a Transient fault — an event the control board recorded that may still be intermittent. The same fault number often appears both ways (for example T013 and A013): the T version is usually the earlier stage and the A version is the persistent fault that shut the furnace down. A T code is not automatically minor — always check the Severity column, since some transient faults are still High and need a professional.

Asterisk (*). A code marked with an asterisk applies only to two-stage models. If your furnace is single-stage, you can ignore the asterisked codes.

How to Read the Error Code

The Integrated Furnace Control (IFC) uses Bluetooth communicating fault codes displayed via the contractor app. Codes use alphanumeric format with A (Active fault) or T (Transient fault) prefix followed by a 3-digit number and _F suffix. Active faults indicate a currently present condition; transient faults indicate an intermittent condition. Codes marked with * are two-stage only faults. All lockout conditions can be cleared by cycling power off and then back on. The furnace control will not initiate a heat cycle during any lockout condition.

About This Model

The Rheem R802VA07542117MSA is a two-stage, variable speed gas furnace using the Bluetooth Communicating IFC control board.