Rheem R802VA07542117MSA Furnace Error Codes

Two-Stage, Variable Speed Gas Furnace | Control Board: Bluetooth Communicating IFC

Not your model? View all Rheem models →

Disclaimer
This information is for reference purposes only and does not guarantee accuracy or completeness. Always consult your owner's manual and a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

All Error Codes

Code Name Severity DIY?
A001_F Model Data Configuration Error High ✗ Call a pro
A002_F Blower Coefficient Configuration Error High ✗ Call a pro
A011_F Failed Ignition High ✓ Yes
T013_F Flame Lost after Established High ✓ Yes
A013_F Flame Lost after Established High ✓ Yes
A014_F Flame Present with Gas Valve Off High ✗ Call a pro
T022_F Main Limit Switch Open High ✓ Yes
A022_F Main Limit Switch Open High ✓ Yes
A031_F Open Fuse High ✗ Call a pro
A033_F Roll-Out Switch Alarm High ✗ Call a pro
A044_F Inducer Lo Pressure Switch Won't Open High ✗ Call a pro
T045_F Inducer Lo Pressure Switch Won't Close High ✓ Yes
T047_F Inducer Fan 5 Minute Lockout Low ✓ Yes
A047_F Inducer Fan 5 Minute Lockout High ✓ Yes
T055_F Inducer Hi Pressure Switch Won't Open High ✗ Call a pro
A055_F Inducer Hi Pressure Switch Won't Open High ✗ Call a pro
T057_F Inducer Hi Pressure Switch Won't Close High ✓ Yes
A061_F Blower Fault - Motor Cannot Run High ✗ Call a pro
T081_F Return Air Sensor Fault Low ✗ Call a pro
T082_F Supply Air Sensor Fault Low ✗ Call a pro
T084_F Outdoor Air Sensor Fault Low ✗ Call a pro
T085_F Suction Line Temp Thermistor Failure Low ✗ Call a pro
T086_F Suction Pressure Sensor Failure Low ✗ Call a pro
T087_F Power Board Temp Sensor Fault Low ✗ Call a pro
T088_F EXV Sensor Measurement Error Low ✗ Call a pro
A093_F Internal Control Fault Detected High ✗ Call a pro
A111_F One-hour Lockout: Main Limit Switch High ✓ Yes
A113_F One-hour Lockout: Ignition Failure High ✓ Yes
A114_F One-hour Lockout: Flame Lost Failure High ✓ Yes
A115_F One-hour Lockout: Gas Valve Stuck Closed High ✗ Call a pro
A116_F One-hour Lockout: Flame Presence Alarm High ✗ Call a pro
T117_F Detect RPM Motor Failure High ✗ Call a pro
A117_F Detect RPM Motor Failure High ✗ Call a pro
A126_F Flame not Sensed with Gas Valve On - UL High ✗ Call a pro
A127_F Flame Present with Gas Valve Off - UL High ✗ Call a pro
A221_F Configuration Data Restore Failure High ✗ Call a pro
A222_F Model Data Restore Failure High ✗ Call a pro
A223_F Internal Fault: Monitor Chip Comm Failure High ✗ Call a pro
A224_F Flame Status Circuit Failure High ✗ Call a pro
A225_F Internal Fault: Gas Vlv 1 Rly Welded Shut High ✗ Call a pro
A226_F Internal Fault: Gas Vlv 1 Rly Stuck Open High ✗ Call a pro
A227_F Internal Fault: Gas Vlv 2 Rly Welded Shut High ✗ Call a pro
A228_F Internal Fault: Gas Vlv 2 Rly Stuck Open High ✗ Call a pro

How to Read the Error Code

The Integrated Furnace Control (IFC) uses a Bluetooth communicating interface with alphanumeric fault codes in the format [A|T]NNN_F. Codes prefixed with 'A' are alarm faults and codes prefixed with 'T' are troubleshooting faults. A blinking LED flashes the fault code number digit by digit with a 3-second delay between digits. For detailed fault code and troubleshooting information, connect to the furnace via Bluetooth and the contractor app. Codes marked with * are two-stage only faults.

About This Model

The Rheem R802VA07542117MSA is a two-stage, variable speed gas furnace using the Bluetooth Communicating IFC control board.