Error Code T117_F
High

Rheem R802VA07542117MSA Error Code T117_F: Detect RPM Motor Failure

TL;DR
The Rheem R802VA blower motor is not spinning at the expected RPM. The furnace may still operate but heating and cooling airflow will be incorrect. A technician should diagnose the blower motor.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code T117_F Mean?

Fault code T117_F on the Rheem R802VA indicates that the IFC has detected the blower motor RPM does not match the commanded target speed. The R802VA uses a constant CFM ECM (electronically commutated motor) blower; the IFC sends a speed command to the motor and monitors the feedback RPM signal. When the actual RPM deviates significantly from the target, T117_F is set.

The T (troubleshooting) prefix means this was observed intermittently rather than as an ongoing locked-out condition. However, incorrect blower speed means the furnace is not delivering the designed airflow for heating or cooling, which affects comfort, efficiency, and the thermal loading on the heat exchanger.

Common causes include worn motor bearings that cause speed instability, a failing ECM motor control module that cannot maintain commanded speed, a dirty or unbalanced blower wheel that creates load fluctuations, or wiring issues between the IFC and the motor module. Because ECM motors have the control electronics physically attached to the motor body, diagnosing whether the motor winding or the module is at fault requires professional testing.

Common Causes

Cause Likelihood DIY?
Blower motor bearing wear causing speed variations Most common ✗ Call a pro →
ECM motor module failure Common ✗ Call a pro →
Dirty blower wheel causing motor strain Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.