Rheem R802VA07542117MSA Error Code A031_F: Open Fuse

TL;DR
The 24VAC low-voltage fuse on the Rheem R802VA control board has blown, almost always due to a short circuit in the thermostat wiring. The underlying short must be found before the fuse is replaced.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code A031_F Mean?

Fault code A031_F on the Rheem R802VA means the low-voltage fuse protecting the 24VAC circuit on the IFC board has opened (blown). The IFC reports fault code 30 via Bluetooth when this fuse has been opened. With this fuse blown, the control board, thermostat, and all 24VAC accessories lose power and the furnace cannot operate.

The 24VAC fuse protects the circuit from short circuits between the 24VAC hot leg and the Ground or Common (C) wire. The most common cause is thermostat wiring where two wires have shorted together — for example, where wire insulation has worn away at a nail or staple, or where a wire terminal has been incorrectly connected. A defective thermostat or an accessory such as a zone controller, humidifier, or UV light can also cause the short.

Simply replacing the fuse without finding and correcting the short will cause the new fuse to blow immediately or shortly after. A technician must systematically isolate the 24VAC circuit — disconnecting the thermostat wires at the board and each accessory — to locate the fault before installing a new fuse.

Common Causes

Cause Likelihood DIY?
Short circuit in thermostat wiring Most common ✗ Call a pro →
Shorted thermostat wire touching common or ground Common ✗ Call a pro →
Defective thermostat or accessory causing short Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Installation Instructions - 80+ Upflow/Horizontal Two-Stage and Single-Stage Bluetooth Communicating Gas Furnaces with Constant CFM/PWM Blower

✓ Verified against manufacturer service manual — March 2026