Error Code T055_F
High

Rheem R802VA07542117MSA Error Code T055_F: Inducer Hi Pressure Switch Won't Open

TL;DR
On a two-stage Rheem R802VA, the high-stage inducer pressure switch is stuck closed when it should be open. This is a two-stage-only fault requiring technician service.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code T055_F Mean?

Fault code T055_F on the Rheem R802VA is a troubleshooting-level fault that occurs only on two-stage models. It indicates that the high-stage inducer pressure switch is remaining closed when the IFC expects it to be open. In a two-stage furnace, there are separate pressure switch circuits for low-stage and high-stage operation; the high-stage switch should be open at rest and only close when the inducer is running at high speed and building sufficient draft pressure.

When the high-stage switch is stuck closed before inducer operation begins, the IFC detects an incorrect state and cannot confirm proper switching behavior during startup. This prevents safe transition to high-stage heating.

The T (troubleshooting) prefix means this fault was observed intermittently rather than as an ongoing alarm condition. Possible causes include a mechanical failure in the high-stage pressure switch, a partially blocked sensing hose that traps residual negative pressure, or a defective switch with welded contacts.

Common Causes

Cause Likelihood DIY?
High-stage pressure switch stuck in closed position Most common ✗ Call a pro →
Pressure switch hose maintaining pressure keeping switch closed Common ✗ Call a pro →
Defective pressure switch with welded contacts Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Installation Instructions - 80+ Upflow/Horizontal Two-Stage and Single-Stage Bluetooth Communicating Gas Furnaces with Constant CFM/PWM Blower

✓ Verified against manufacturer service manual — March 2026