Error Code A225_F
High

Rheem R802VA07542117MSA Error Code A225_F: Internal Fault: Gas Vlv 1 Rly Welded Shut

TL;DR
A relay on the Rheem R802VA control board that controls gas valve 1 has welded shut, so the furnace cannot stop sending power to the gas valve. Turn off the gas supply immediately and call a technician.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code A225_F Mean?

Fault code A225_F on the Rheem R802VA indicates that the relay on the IFC board controlling gas valve 1 has welded (fused) shut. Electrical relays can weld when a large current arc fuses the contact surfaces together. Once welded, the relay cannot open regardless of the command signal from the main processor — meaning the gas valve remains continuously energized even when the IFC tries to shut it off.

This is a critical safety fault. A gas valve that cannot be de-energized will remain open, allowing gas to flow to the burners whenever they cool down enough to ignite, and potentially during periods when no combustion is expected. The furnace cannot be safely operated in this state.

The welded relay is physically part of the IFC board and cannot be repaired individually. The entire control board must be replaced. Before service, the manual gas supply valve should be turned off to prevent any gas flow through the stuck-open valve pathway.

Common Causes

Cause Likelihood DIY?
Gas valve relay contacts welded due to electrical arcing Most common ✗ Call a pro →
Control board component failure Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Installation Instructions - 80+ Upflow/Horizontal Two-Stage and Single-Stage Bluetooth Communicating Gas Furnaces with Constant CFM/PWM Blower

✓ Verified against manufacturer service manual — March 2026