This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code A002_F Mean?

Fault code A002_F on the Rheem R802VA indicates that the IFC board has detected invalid or absent blower coefficient data. The R802VA uses a constant CFM/PWM blower motor whose speed is calculated from mathematical coefficients stored in the IFC. These coefficients define the precise relationship between the requested airflow and the motor command signal.

Without correct blower coefficients, the IFC cannot accurately control the ECM (electronically commutated motor) blower, meaning airflow for heating, cooling, and continuous fan modes would all be incorrect or the blower would not run at all. As a result, the board locks out with A002_F.

This fault most commonly occurs after a control board replacement when the replacement board has not been fully programmed through the Bluetooth contractor app. It can also occur if a blower motor replacement involved an incompatible motor that requires different coefficient values.

Common Causes

Cause Likelihood DIY?
Replacement control board missing blower coefficient data Most common ✗ Call a pro →
Blower motor replacement with incompatible coefficients Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Installation Instructions - 80+ Upflow/Horizontal Two-Stage and Single-Stage Bluetooth Communicating Gas Furnaces with Constant CFM/PWM Blower

✓ Verified against manufacturer service manual — March 2026