Error Code T085_F
Low

Rheem R802VA07542117MSA Error Code T085_F: Suction Line Temp Thermistor Failure

TL;DR
On a two-stage Rheem R802VA, the suction line temperature thermistor used for EXV superheat control has failed. Heating is unaffected but cooling efficiency may be impaired. A technician should replace the thermistor.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code T085_F Mean?

Fault code T085_F on the Rheem R802VA is a troubleshooting-level fault for two-stage models only. It indicates that the suction line temperature thermistor — a sensor used by the Electronic Expansion Valve (EXV) system for refrigerant superheat control — has failed or is reading outside the valid range.

The EXV (Electronic Expansion Valve) system is part of the cooling side of the HVAC system and controls refrigerant flow through the air conditioning coil. The suction line thermistor measures the temperature of refrigerant returning to the compressor; this data, combined with the suction pressure reading, allows the EXV controller to compute superheat and adjust the valve accordingly for efficient cooling operation.

Because this sensor relates to the cooling system rather than the heating combustion system, furnace heating should continue to operate normally with this fault code active. However, cooling performance may be degraded or the EXV may default to a fixed position without accurate superheat data. The T prefix indicates an intermittent condition.

Common Causes

Cause Likelihood DIY?
Failed suction line temperature thermistor Most common ✗ Call a pro →
Disconnected thermistor wiring at control board Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Installation Instructions - 80+ Upflow/Horizontal Two-Stage and Single-Stage Bluetooth Communicating Gas Furnaces with Constant CFM/PWM Blower

✓ Verified against manufacturer service manual — March 2026