Error Code T088_F
Low

Rheem R802VA07542117MSA Error Code T088_F: EXV Sensor Measurement Error

TL;DR
On a two-stage Rheem R802VA, the EXV sensor system is producing inconsistent measurements. Heating is unaffected but cooling performance may be reduced. A technician should diagnose the EXV sensor circuit.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code T088_F Mean?

Fault code T088_F on the Rheem R802VA is a troubleshooting-level fault for two-stage models only. It indicates that the Electronic Expansion Valve (EXV) sensor measurements are inconsistent or outside the expected range. The EXV system uses the combination of suction line temperature (T085_F) and suction pressure (T086_F) to compute superheat; T088_F indicates a measurement error in this combined sensing system rather than a failure in just one sensor.

The EXV is an electronically controlled valve that regulates refrigerant flow through the cooling coil. Accurate superheat measurement is necessary for the EXV to maintain optimal refrigerant charge in the evaporator coil, affecting cooling efficiency and system longevity. When the measurement system reports inconsistent data, the EXV may not operate correctly.

As with other EXV-related faults, furnace heating is not affected by T088_F. The T prefix indicates an intermittent occurrence. Possible causes include wiring issues between sensors and the EXV controller, a failed sensor, or intermittent refrigerant pressure fluctuations causing sensor readings to temporarily go out of the expected range.

Common Causes

Cause Likelihood DIY?
Failed EXV sensor or transducer Most common ✗ Call a pro →
Wiring issue between EXV sensor and control board Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Installation Instructions - 80+ Upflow/Horizontal Two-Stage and Single-Stage Bluetooth Communicating Gas Furnaces with Constant CFM/PWM Blower

✓ Verified against manufacturer service manual — March 2026