Error Code A117_F
High

Rheem R802VA07542117MSA Error Code A117_F: Detect RPM Motor Failure

TL;DR
The Rheem R802VA blower motor has a persistent RPM failure — it cannot maintain the commanded speed. The motor or its ECM control module has likely failed and needs replacement by a technician.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code A117_F Mean?

Fault code A117_F on the Rheem R802VA is the alarm-level (persistent) counterpart to T117_F. It indicates that the blower motor RPM failure is an ongoing condition rather than an intermittent one. The IFC has detected the motor is continuously unable to achieve or maintain the target speed, triggering the A (alarm) classification.

The R802VA uses a constant CFM ECM blower that receives speed commands from the IFC via a PWM signal. The ECM motor continuously monitors its own RPM and reports back to the IFC. When the motor cannot match the commanded RPM persistently, A117_F is set. This condition prevents the furnace from delivering proper airflow for heating, cooling, or continuous fan operation.

With a persistent RPM fault, the motor's ability to circulate air reliably is compromised. The ECM motor module (the electronics bolted to the motor body) is the most common point of failure when RPM feedback is continuously incorrect. Motor winding failure and bearing wear can also produce this symptom. Unlike T117_F which may recover on its own, A117_F indicates the fault has been confirmed as an active ongoing condition.

Common Causes

Cause Likelihood DIY?
Failed blower motor Most common ✗ Call a pro →
Failed ECM motor control module Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Installation Instructions - 80+ Upflow/Horizontal Two-Stage and Single-Stage Bluetooth Communicating Gas Furnaces with Constant CFM/PWM Blower

✓ Verified against manufacturer service manual — March 2026