Error Code A127_F
High

Rheem R802VA07542117MSA Error Code A127_F: Flame Present with Gas Valve Off - UL

TL;DR
The Rheem R802VA is detecting flame when the gas valve should be closed — a critical UL safety fault. Shut off the gas supply immediately and call a technician. Do not restart the furnace.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code A127_F Mean?

Fault code A127_F on the Rheem R802VA is a UL (Underwriters Laboratories) safety fault similar to A014_F, but specifically classified as a UL compliance safety alarm. It occurs when the flame sensor detects flame presence while the IFC has confirmed the gas valve relay is open (valve should be off). This indicates that either the gas valve is stuck open and continuing to supply gas, or the flame sensor circuit is producing a false positive signal.

The UL designation makes A127_F a higher-severity classification than A014_F even though both detect the same physical condition of undesired flame. UL safety faults are directly tied to the safety certifications that allow the furnace to be legally installed and operated in the United States. When a UL fault is active, the furnace has violated a certified safe operating condition.

A gas valve stuck in the open position is the primary safety concern. If the valve cannot be confirmed closed, gas will continue to flow even when the furnace is in a lockout state, creating a combustion or carbon monoxide risk. The control board relay may also have failed in a welded-closed state, keeping voltage applied to the gas valve regardless of the IFC command.

Common Causes

Cause Likelihood DIY?
Gas valve stuck in open position Most common ✗ Call a pro →
Faulty flame sensing circuit giving false positive Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Installation Instructions - 80+ Upflow/Horizontal Two-Stage and Single-Stage Bluetooth Communicating Gas Furnaces with Constant CFM/PWM Blower

✓ Verified against manufacturer service manual — March 2026