Error Code A014_F
High

Rheem R802VA07542117MSA Error Code A014_F: Flame Present with Gas Valve Off

TL;DR
The Rheem R802VA flame sensor is detecting a flame when the gas valve should be completely off — a serious safety alarm. Shut off the furnace and gas supply immediately and call a technician.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code A014_F Mean?

Fault code A014_F on the Rheem R802VA means the flame sensor is detecting an undesired flame when the IFC has commanded the gas valve closed. The IFC will initiate a one-hour soft lockout when this condition is detected. Because flame should not exist when the gas valve is off, this fault indicates a potentially dangerous situation.

The most likely cause is a gas valve stuck in the open position, allowing gas to continue flowing and burning after the valve is commanded to close. A relay on the control board that drives the gas valve can also weld shut due to electrical arcing, keeping voltage applied to the valve continuously. Less commonly, a faulty flame sensor circuit may be generating a false flame signal when no actual flame exists.

Regardless of the cause, this fault must not be ignored. If the gas valve is truly stuck open, uncontrolled combustion or gas accumulation could occur. The furnace should be shut down and the gas supply turned off at the manual shutoff valve until a technician has diagnosed the root cause.

Common Causes

Cause Likelihood DIY?
Gas valve stuck in the open position Most common ✗ Call a pro →
Faulty flame sensor circuit giving false readings Common ✗ Call a pro →
Gas valve relay welded shut on control board Uncommon ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.