High

Rheem R802VA07542117MSA Error Code A224_F: Flame Status Circuit Failure

TL;DR
The Rheem R802VA control board's flame sensing circuit has failed internally. The furnace cannot safely detect whether the burners are lit or not. The control board must be replaced by a technician.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code A224_F Mean?

Fault code A224_F on the Rheem R802VA indicates that the flame status sensing circuit on the IFC board has failed. The flame sensing circuit is the electronic circuitry on the board that measures the microamp-level flame rectification current from the flame sensor rod. This circuit converts the small flame current into a digital flame-present or flame-absent signal that the main processor uses to make safety decisions.

When the flame sensing circuit itself has failed — as opposed to the external flame sensor rod failing — the IFC cannot reliably determine whether a flame exists. This is a fundamental safety function: without knowing whether gas is burning, the control board cannot safely operate the gas valve or prevent dangerous conditions such as unburned gas accumulation.

Because the flame sensing circuit is integrated into the control board electronics, this fault cannot be resolved by replacing the external flame sensor rod or its wiring. The IFC board itself must be replaced. After replacement, the new board requires Bluetooth programming with model data and configuration before the furnace will operate.

Common Causes

Cause Likelihood DIY?
Failed flame sensing circuit on control board Most common ✗ Call a pro →
Control board damage from power surge Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes