Error Code T082_F
Low

Rheem R802VA07542117MSA Error Code T082_F: Supply Air Sensor Fault

TL;DR
On a two-stage Rheem R802VA, the supply air temperature sensor has failed or is out of range. The furnace may still operate but cannot monitor discharge air temperature accurately. A technician should replace the sensor.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code T082_F Mean?

Fault code T082_F on the Rheem R802VA is a troubleshooting-level fault that applies only to two-stage models. It indicates that the supply air temperature sensor — which monitors the temperature of heated air leaving the heat exchanger and entering the supply ductwork — has failed or is reading outside the expected range.

In a two-stage R802VA furnace, the supply air sensor helps the IFC monitor heat exchanger performance and can be used to detect conditions like excessive supply air temperature that could indicate airflow restriction. When this sensor is unavailable, the furnace loses visibility into supply air temperature but may continue operating in a degraded mode.

The T (troubleshooting) prefix means this is an intermittent rather than persistent fault — the furnace may continue running and the code may clear on its own. In practice, this means if the code disappeared after a cycle or appeared only once, the cause is likely a loose connector or corroded pins rather than a fully failed sensor. Possible causes include a failed supply air thermistor, a disconnected or damaged sensor wire, or corroded connector terminals at the sensor or the control board. A technician should check the connector first before replacing the sensor.

Common Causes

Cause Likelihood DIY?
Failed supply air temperature thermistor Most common ✗ Call a pro →
Disconnected sensor wiring Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes