Error Code A044_F
High

Ruud U802VA050317MSA Error Code A044_F: Inducer Lo Pressure Switch Won't Open

TL;DR
The Ruud U802VA low-stage pressure switch is stuck closed when it should be open. The furnace cannot safely verify draft before ignition. A technician must inspect and likely replace the pressure switch.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code A044_F Mean?

Fault code A044_F on the Ruud U802VA is an active fault indicating that the low-stage inducer pressure switch is remaining in the closed position when the IFC expects it to be open. The pressure switch is a safety device that verifies the inducer motor is creating proper exhaust draft before the furnace is permitted to attempt ignition.

When the inducer is off, the pressure switch should be open — meaning no draft pressure is present. If the switch is stuck closed before the inducer runs, the IFC detects an incorrect sequence and blocks the ignition attempt. A stuck-closed switch could indicate a mechanically failed diaphragm inside the switch, a blocked sensing hose that maintains residual pressure at the switch, or contacts that have welded together.

The U802VA's pressure switch hose may also accumulate condensation over time, particularly in humid environments. Moisture trapped in the sensing hose can create enough hydrostatic pressure to keep the diaphragm deflected even when the inducer is off. A technician can inspect the hose for water accumulation before concluding the switch itself has failed.

Common Causes

Cause Likelihood DIY?
Stuck pressure switch Most common ✗ Call a pro →
Blocked pressure switch hose Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Installation Instructions - 80+ Upflow/Horizontal Two-Stage and Single-Stage Bluetooth Communicating Gas Furnaces

✓ Verified against manufacturer service manual — March 2026