Error Code 44
High

Rheem R96VA0702317MSA Error Code 44: Low Pressure Switch Closed, Inducer Off

TL;DR
Code 44 means the low pressure switch is closed when it should be open and the inducer is not running — a serious venting safety issue. The furnace will not heat. A technician must inspect and replace the pressure switch.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code 44 Mean?

A code 44 on the Rheem R96VA0702317MSA is a critical fault indicating the low pressure switch is in the closed position before the heating cycle begins, when the inducer motor is not running. The pressure switch should only be closed when the inducer creates sufficient negative pressure in the venting system. Finding the switch already closed with the inducer off signals a serious malfunction — the pressure switch may be stuck or has been deliberately bypassed, either of which compromises the furnace's ability to verify safe venting conditions before ignition.

The IFC checks the pressure switch position at the start of every heat cycle as a safety verification step. If the switch is already closed before the inducer starts, the furnace knows the switch cannot be trusted to accurately reflect venting conditions, and it refuses to proceed with ignition. Cooling and fan-only modes remain operational since this check is only performed in gas heating modes.

A pressure switch that is welded or stuck closed is the most common cause. Deliberate bypassing of the pressure switch — an unauthorized and dangerous modification that removes a key safety layer — is another documented cause. Less commonly, an abnormally high negative pressure already present in the venting system from an unusual installation configuration can close the switch without the inducer running. A technician must determine the cause and replace or restore the pressure switch.

Common Causes

Cause Likelihood DIY?
Faulty pressure switch welded closed Most common ✗ Call a pro →
Pressure switch physically bypassed in the field Common ✗ Call a pro →
Loose or faulty wiring Uncommon ✗ Call a pro →
Abnormally high negative pressure present on vent system without inducer running Uncommon ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Installation Instructions for 4 Position Condensing Two-Stage, Communicating Gas Furnaces w/ECM Blower (-)96V Series & (-)(-)96MDV Series

✓ Verified against manufacturer service manual — March 2026