Error Code 44
High

Ruud U96VA0702317MSA Error Code 44: Low Pressure Switch Closed, Inducer Off

TL;DR
Code 44 means the low pressure switch is closed when the inducer is not running — a serious safety issue. The furnace will not heat. A technician must inspect and replace the pressure switch and check for bypasses.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code 44 Mean?

A code 44 on the Ruud U96VA0702317MSA is a critical fault indicating the low pressure switch is in the closed position before the heating cycle begins, when the inducer motor is not running. The pressure switch should only close when the running inducer creates sufficient negative pressure in the venting system. Finding it already closed before the inducer starts indicates the switch has failed, is stuck, or has been deliberately bypassed — any of which means the furnace cannot rely on this switch to verify safe venting. Gas heating is blocked while cooling and fan-only modes remain available.

The IFC performs a pre-ignition safety check on the pressure switch at the start of every heat cycle. If the switch is already closed, the IFC determines it cannot trust this safety device to reflect actual venting conditions and refuses to proceed with ignition. A pressure switch with mechanically stuck or welded contacts is the most common hardware failure. Deliberate bypassing of the pressure switch — sometimes done as a temporary field workaround — removes a critical safety layer and is a dangerous modification.

An abnormally high negative pressure already present in the vent system before furnace startup is a less common cause. A technician must determine the exact cause — stuck switch, bypass, or unusual system pressure — and correct it before gas heating can resume.

Common Causes

Cause Likelihood DIY?
Pressure switch stuck closed or bypassed Most common ✗ Call a pro →
High negative pressure in vent system without inducer running Uncommon ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.