Error Code 45
High

Ruud U96VA0702317MSA Error Code 45: Low Pressure Switch Open, Inducer on High Speed

TL;DR
Code 45 means the low pressure switch didn't close when the inducer ran at high speed before ignition. The furnace cannot verify safe venting and will not ignite. Check for blocked vent pipes outside; a technician must diagnose further.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code 45 Mean?

A code 45 on the Ruud U96VA0702317MSA is a critical fault indicating the low pressure switch failed to close even though the inducer motor was running at high speed during the pre-ignition sequence. The U96VA always ignites at high fire, so this check happens every heat cycle. The switch must close after the inducer starts and before the IFC can open the gas valve for ignition — if it does not close, the ignition sequence is blocked. Cooling and fan-only modes remain available.

The most common cause is a physical obstruction in the exhaust or intake venting system. Ice and snow blocking vent terminations outside the home are frequent causes during winter. Bird nests, debris, or leaves at the vent outlets cause similar problems during other seasons. Vent pipe runs that are too long or use too many elbows — exceeding the maximum specifications in the installation manual — create airflow resistance that prevents the inducer from building sufficient negative pressure. A faulty or disconnected inducer motor, pressure switch hoses that are split, kinked, or disconnected inside the furnace, or a faulty pressure switch itself are additional causes.

As a first step, check the exterior vent pipe terminations for visible obstructions. If the vents are clear and code 45 continues, a technician must inspect the full system.

Common Causes

Cause Likelihood DIY?
Vent blockage or improper termination Most common ✗ Call a pro →
Faulty inducer motor or disconnected pressure switch hoses Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Installation Instructions for (-)96V Series & (-)(-)96MDV Series

✓ Verified against manufacturer service manual — March 2026