Error Code 46
High

Ruud U96VA0702317MSA Error Code 46: Low Pressure Switch Open, Inducer on Low Speed

TL;DR
Code 46 means the low pressure switch opened when the inducer switched to low speed during low-stage heating. The furnace drops back to attempting restart. A technician must inspect the venting system and determine if low-fire draft requirements are being met.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code 46 Mean?

A code 46 on the Ruud U96VA0702317MSA is a critical fault indicating the low pressure switch opened when the inducer was running at low speed. This fault only occurs after the furnace has successfully ignited at high fire and the IFC attempts to transition to low-stage heating by reducing inducer speed. During this transition, if the reduced inducer speed cannot maintain enough negative pressure to keep the low pressure switch closed, code 46 triggers. The gas valve is immediately de-energized, the furnace runs post-purge and blower off-delay, then attempts to restart.

The low-fire operating condition is inherently more sensitive to venting restrictions than high-fire, because the inducer runs slower and generates less negative pressure. A venting problem that is marginal at high fire may reliably fail at low fire. Common causes include partially blocked vent terminations or piping, vent run configurations near the upper limits of the installation specification, failing inducer motors that struggle to maintain speed under load, high-altitude installations where thinner air reduces inducer efficiency, and faulty pressure switches.

A technician needs to evaluate the entire venting system — pipe lengths, elbow counts, termination conditions — against the specifications for this model, as well as test the inducer motor performance and pressure switch operation.

Common Causes

Cause Likelihood DIY?
Vent blockage or improper termination Most common ✗ Call a pro →
High altitude installation without proper kit Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Installation Instructions for (-)96V Series & (-)(-)96MDV Series

✓ Verified against manufacturer service manual — March 2026