Rheem R96VA0702317MSA Error Code d6: Horsepower Conflict on Memory Card

TL;DR
Code d6 means the blower motor's horsepower doesn't match what the memory card says it should be, though the furnace operates normally using the control board's internal data. A technician should verify the motor and card are the correct parts.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code d6 Mean?

A d6 code on the Rheem R96VA0702317MSA is a non-critical fault indicating a horsepower mismatch between the installed blower motor and the model data on the memory card at connector P6. The motor reports its HP rating to the IFC, which compares it against the HP specification stored on the memory card. When there is a discrepancy, d6 is displayed. Importantly, the model data stored directly on the IFC microprocessor does match the installed motor, so the furnace continues to operate normally. The d6 code appears only during standby mode.

This fault most commonly appears after a service call where either the blower motor was replaced with a unit of a different HP rating, or the memory card or control board was replaced with one from a different model. The two-stage ECM blower used in this furnace family comes in different HP ratings depending on the BTU capacity and airflow requirements of each model, so substituting parts from different models can produce this mismatch.

While the furnace continues to operate with d6 active, the underlying parts mismatch should be corrected. Running with a motor that does not match the model's specifications can result in improper airflow, insufficient heat exchanger cooling, and potential long-term damage. A technician should verify that both the installed motor and memory card are the correct parts for this specific model.

Common Causes

Cause Likelihood DIY?
Blower motor recently replaced with wrong horsepower motor Most common ✗ Call a pro →
Memory card or furnace control recently replaced with wrong card Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Installation Instructions for 4 Position Condensing Two-Stage, Communicating Gas Furnaces w/ECM Blower (-)96V Series & (-)(-)96MDV Series

✓ Verified against manufacturer service manual — March 2026