Error Code 33
High

Rheem R96VA0702317MSA Error Code 33: Over-Temperature Switch (Roll-Out) Open

TL;DR
Code 33 is a serious safety alert — the rollout limit switch has tripped because flames escaped the heat exchanger into the burner compartment. The furnace will not heat until a technician identifies the cause and manually resets the switch.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code 33 Mean?

A code 33 on the Rheem R96VA0702317MSA means the Manually Reset Limit Control (MRLC), also known as the rollout limit switch, has tripped. This switch is designed to detect flame rollout — a condition where flames escape from the normal combustion area within the heat exchanger and enter the burner compartment. Flame rollout is a serious safety event that can cause fire or carbon monoxide poisoning if left unaddressed. Cooling and fan-only modes continue to work, but the furnace will not provide gas heat.

Rollout occurs when combustion gases cannot follow their normal path through the heat exchanger and out the flue. Instead, they are forced backward and outward, bringing flames into the burner compartment. The most common cause is insufficient venting — a blocked exhaust pipe, an excessively long or restricted flue run, or an intake pipe obstruction can all create enough backpressure to force flame rollout. Other causes include an unstable flame pattern from burner assembly issues, damaged heat exchanger tubes that allow cross-flow, or loose wiring that caused the code to appear without actual rollout.

The rollout limit switch is a manual-reset type by design, meaning a technician must physically press the reset button to acknowledge this serious fault. Resetting the switch without identifying and correcting the root cause is dangerous — the rollout condition will simply recur.

Common Causes

Cause Likelihood DIY?
Insufficient venting through either the inlet or exhaust Most common ✗ Call a pro →
Loose or faulty wiring Common ✗ Call a pro →
Unstable flame pattern Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Installation Instructions for 4 Position Condensing Two-Stage, Communicating Gas Furnaces w/ECM Blower (-)96V Series & (-)(-)96MDV Series

✓ Verified against manufacturer service manual — March 2026