All Error Codes

Code Name Severity DIY?
d1 No Model Data High ✗ Call a pro →
d4 No Valid Model Data on Memory Card Low ✗ Call a pro →
d6 Horsepower Conflict on Memory Card Low ✗ Call a pro →
10 One-Hour Lockout High ✗ Call a pro →
11 Failed Ignition High ✓ Yes →
12 Low Flame Sense Low ✓ Yes →
13 Flame Lost After Established Low ✓ Yes →
14 Flame Present with Gas Valve Off High ✗ Call a pro →
22 Main Limit Open High ✓ Yes →
23 HALC Open High ✗ Call a pro →
26 Line and Neutral Reversed or Poor Ground High ✗ Call a pro →
30 Open Fuse High ✗ Call a pro →
33 Over-Temperature Switch (Roll-Out) Open High ✗ Call a pro →
44 Low Pressure Switch Closed, Inducer Off High ✗ Call a pro →
45 Low Pressure Switch Open, Inducer on High Speed High ✗ Call a pro →
46 Low Pressure Switch Open, Inducer on Low Speed High ✗ Call a pro →
55 High Pressure Switch Closed, Inducer Off High ✗ Call a pro →
57 High Pressure Switch Open, Inducer on High Speed High ✗ Call a pro →
58 Water Circuit Open High ✗ Call a pro →
59 Water Sensed High ✗ Call a pro →
60 Blower Fault - Blower Can Still Run Low ✓ Yes →
61 Blower Fault - Motor Cannot Run High ✗ Call a pro →
66 Blower Cutback Low ✓ Yes →
68 No Blower Communications High ✗ Call a pro →
93 Internal Control Fault Detected High ✗ Call a pro →
99 Remote Faults Reset Performed Info — →

How to Read the Error Code

The R96V control board has a small two-digit numeric display that shows error codes when something goes wrong. Each code flashes on and off in a repeating pattern until the problem is resolved. Codes are divided into two levels: Level 1 faults are minor issues where the furnace can continue running but may not perform optimally, while Level 2 faults are serious problems that shut down the furnace. Lower code numbers indicate higher-priority issues.

About This Model