Error Code 93
High

Rheem R96VA0702317MSA Error Code 93: Internal Control Fault Detected

TL;DR
Code 93 means the IFC has detected a severe internal control fault — a microprocessor failure or unexpected voltage to the gas valve. The furnace is completely shut down. A technician must replace the control board.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code 93 Mean?

A code 93 on the Rheem R96VA0702317MSA is a severe and rare fault indicating a critical internal failure in the integrated furnace control board. This code can represent one of two conditions: an internal microprocessor fault detected by the IFC's self-diagnostic routines, or unexpected voltage detected at the main gas valve solenoid when the IFC has not commanded the valve to open. Both conditions are serious and should rarely occur in a properly installed and maintained furnace.

When code 93 is triggered during a heating call, the gas valve closes immediately, all outputs are de-energized, and the furnace shuts down. The IFC may display codes 93 and 10 alternately, indicating the severe fault has also pushed the furnace into soft lockout. This lockout cannot be cleared by simply cycling the thermostat — the underlying fault must be addressed first.

The most likely cause is a failed IFC control board that needs replacement. Mis-wiring that sends 24-volt AC to the gas valve solenoid circuit when it should not be present can also trigger this code, though wiring faults are less common. A technician should first check for any obvious wiring anomalies at the gas valve solenoid connection before condemning the IFC. If wiring is correct, the IFC board requires replacement with the correct part for the R96VA0702317MSA.

Common Causes

Cause Likelihood DIY?
24VAC or similar voltage applied to the main gas valve solenoid circuit unexpectedly Most common ✗ Call a pro →
Furnace control software test failure — failed furnace control (or I.F.C.) Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.