Error Code E 310
Low

Lennox EL296UHV Error Code E 310: Discharge Error Temperature Sensor Failure

TL;DR
Your Lennox EL296UHV's discharge air temperature sensor has failed or is reading out of range. The furnace will continue to operate but cannot monitor supply air temperature.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code E 310 Mean?

Error code E310 on the Lennox EL296UHV indicates that the discharge air temperature sensor has failed. The sensor is either shorted or reading a value outside the expected range. This sensor measures the temperature of the air leaving the furnace and entering the ductwork.

The control board uses discharge temperature data to monitor furnace performance and detect conditions like restricted airflow or excessive heat. Without a functioning sensor, the board loses this monitoring capability. The furnace will still heat, but it cannot perform temperature-based safety checks or performance adjustments that rely on this sensor.

In communicating mode, the error clears 30 seconds after the sensor fault recovers. In non-communicating mode, it clears after the current heat call is completed. A technician should compare the sensor's resistance to the temperature/resistance chart in the installation instructions and replace the sensor if it is out of specification.

When to Call a Professional

Contact a licensed HVAC technician if:

Sources