Error Code E 225
High

Lennox EL296UHV Error Code E 225: High Pressure Switch Failed Open

TL;DR
Your Lennox EL296UHV's high pressure switch has failed to close, meaning the furnace cannot verify safe venting at higher firing rates.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code E 225 Mean?

Error code E225 on the Lennox EL296UHV indicates that the high pressure switch failed to close during a call for heat. The high pressure switch requires a stronger draft than the low pressure switch because it must confirm safe venting conditions for high-fire operation.

When the combustion air inducer motor runs, it creates a vacuum in the vent system. The high pressure switch monitors this vacuum and closes only when draft is strong enough for safe high-fire combustion. If the switch does not close, the furnace may still be able to light on low fire if the low pressure switch closes, but it will not reach full heating output.

The most common cause is a partial blockage in the exhaust vent or combustion air intake — even a small restriction like ice buildup, debris in the vent termination, or a partially blocked screen can prevent the higher draft threshold from being reached. A failing inducer motor losing speed, cracked pressure switch hoses, or a faulty pressure switch itself are also possible causes.

When to Call a Professional

Contact a licensed HVAC technician if:

Sources

  1. Lennox EL296UHV Unit Information (Corp. 1125-L5)

✓ Verified against manufacturer service manual — March 2026