Error Code E 117
Low

Lennox EL296UHV Error Code E 117: Poor Ground Detected

TL;DR
Your Lennox EL296UHV has detected a poor electrical ground. This is a warning — the system continues operating, but the ground connection should be improved.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code E 117 Mean?

Error code E117 on the Lennox EL296UHV is a warning that the control board has detected a degraded ground connection. Unlike E112 (ground not detected), which shuts the system down, E117 is a warning-only code — the furnace continues to operate but with reduced safety margin.

A poor ground connection means the earth ground path has higher resistance than expected. This can be caused by a loose ground wire terminal at the furnace, corrosion on the ground wire or its connection points, or a degraded grounding electrode at the electrical panel. Over time, connections can loosen from thermal cycling and vibration.

The warning clears automatically 30 seconds after the ground quality improves. While the furnace will continue to operate with this warning, proper grounding is important for flame sensing accuracy and electrical safety. Have an electrician check and tighten the ground connections at the furnace and verify the integrity of the ground path back to the panel.

Common Causes

Cause Likelihood DIY?
Loose or corroded ground wire connection Most common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if: