Error Code E 292
High

Lennox EL296UHV Error Code E 292: Indoor Blower Motor Unable to Start

TL;DR
Your Lennox EL296UHV's indoor blower motor cannot start, likely due to an obstructed blower wheel or seized bearings. A technician needs to inspect the motor assembly.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code E 292 Mean?

Error code E292 on the Lennox EL296UHV indicates that the indoor blower motor is unable to start. The control board has commanded the motor to run, but it is not reaching the expected speed or is not moving at all. The furnace enters a 1-hour soft lockout.

The most common cause is a physically obstructed blower wheel. Debris such as insulation, paper, or other objects can fall into the blower compartment and jam the wheel. Seized motor bearings from age, lack of lubrication, or moisture damage can also prevent the motor from spinning. In some cases, the motor's internal electronic module has failed even though the motor windings are intact.

Without the blower motor running, the furnace cannot circulate heated air through the ductwork. Even if the burners could light, the control board will not allow combustion without adequate airflow because the heat exchanger would overheat. The lockout clears after the blower successfully starts. A technician needs to inspect the blower assembly and replace the motor or wheel if they are damaged.

When to Call a Professional

Contact a licensed HVAC technician if: