Error Code E 112
High

Lennox EL296UHV Error Code E 112: Ground Not Detected

TL;DR
Your Lennox EL296UHV has shut down because it cannot detect a proper electrical ground. An electrician needs to restore the ground connection.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code E 112 Mean?

Error code E112 on the Lennox EL296UHV indicates that the control board cannot detect an earth ground connection. Unlike E117 (poor ground warning), E112 is a critical fault that causes the system to shut down completely. Proper grounding is essential for the flame sensing circuit and overall electrical safety.

The most common cause is a missing or disconnected ground wire at the furnace. This can happen if the ground wire was never connected during installation, if it has corroded and broken at a terminal, or if the ground path back to the electrical panel is interrupted.

The system will resume normal operation within 5 seconds after proper grounding is established. An electrician or HVAC technician should verify that the furnace has a solid earth ground connection, check the ground wire continuity back to the electrical panel, and ensure the panel itself is properly grounded to the home's grounding electrode system.

Common Causes

Cause Likelihood DIY?
Missing or broken ground wire connection Most common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if: