Error Code E 226
Low

Lennox EL296UHV Error Code E 226: High Pressure Switch Failed Closed

TL;DR
Your Lennox EL296UHV's high pressure switch is stuck in the closed position. A technician needs to test the switch and inspect the vent system.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code E 226 Mean?

Error code E226 on the Lennox EL296UHV indicates that the high pressure switch has remained closed when the control board expected it to be open. Similar to E224 for the low pressure switch, this means the high pressure switch is stuck and not responding to actual draft conditions.

The high pressure switch should only close when the combustion air inducer is running at sufficient speed to create the higher draft level needed for high-fire operation. If the switch stays closed regardless of inducer status, it can no longer serve as a reliable safety device — the control board cannot trust it to accurately report venting conditions.

The most likely cause is a mechanically stuck switch diaphragm or contacts that have welded together. Condensation moisture entering the switch housing can also cause the contacts to stick. A technician needs to measure the operating pressure, verify the switch opens and closes at the correct pressure thresholds, and replace it if it is malfunctioning.

When to Call a Professional

Contact a licensed HVAC technician if: