Error Code E 114
Low

Lennox EL296UHV Error Code E 114: Line Voltage Frequency Out of Range

TL;DR
Your Lennox EL296UHV is not receiving standard 60 Hz power. This commonly occurs when running on a generator with incorrect frequency output.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code E 114 Mean?

Error code E114 on the Lennox EL296UHV indicates that the line voltage frequency is outside the acceptable range. The furnace expects standard 60 Hz power (standard for North America). When the frequency deviates significantly from 60 Hz, the control board cannot reliably time its operations and triggers this fault.

The most common cause is operating the furnace on a portable generator that does not produce clean 60 Hz power. Inexpensive generators can have frequency fluctuations, especially under varying loads. Inverter generators typically produce more stable frequency output and are better suited for powering sensitive electronics like modern furnace control boards.

Utility power frequency issues are extremely rare but can occur during major grid disturbances. The alarm clears automatically 5 seconds after proper 60 Hz power is restored. If you need to run the furnace on generator power, use an inverter generator rated for the furnace's wattage requirements.

Common Causes

Cause Likelihood DIY?
Generator power with incorrect frequency Most common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if: