Error Code E 115
Low

Lennox EL296UHV Error Code E 115: Low 24V Power

TL;DR
Your Lennox EL296UHV's 24-volt power supply is too low, often because too many accessories are drawing from the transformer. A technician may need to install a larger transformer.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code E 115 Mean?

Error code E115 on the Lennox EL296UHV indicates that the 24-volt control circuit voltage has dropped below the acceptable range (18 to 30 volts). The control board will attempt to restart if the voltage recovers. This is a power supply issue on the low-voltage side of the system, not the main 120-volt supply.

The most common cause is too many accessories drawing power from the furnace's 24-volt transformer. Devices like powered humidifiers, electronic air cleaners, zone damper controllers, and smart thermostats all draw current from the same transformer. When the combined load exceeds the transformer's capacity, the voltage sags and triggers E115.

The solution typically involves either reducing the load on the transformer (by powering some accessories from a separate transformer) or replacing the existing transformer with a higher-VA (volt-ampere) rated unit. A technician can measure the 24-volt circuit load and determine the appropriate fix. The alarm clears automatically once proper voltage is restored.

Common Causes

Cause Likelihood DIY?
Too many accessories drawing power from 24V transformer Most common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

Sources

  1. Lennox EL296UHV Unit Information (Corp. 1125-L5)

✓ Verified against manufacturer service manual — March 2026