Carrier 58MVP Furnace Error Codes

Variable Speed Gas Furnace | Control Board: Variable Speed Furnace Control

Not your model? View all Carrier models →

Disclaimer
This information is for reference purposes only and does not guarantee accuracy or completeness. Always consult your owner's manual and a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

All Error Codes

Code Name Severity DIY?
Continuous OFF No Power High ✓ Yes →
Continuous ON Normal Operation Info — →
Rapid Flashing Reversed Line Voltage Polarity High ✗ Call a pro →
11 No Previous Code Info — →
12 Blower On After Power Up Info — →
13 Limit Circuit Lockout High ✓ Yes →
14 Ignition Lockout High ✗ Call a pro →
15 Blower Motor Lockout High ✗ Call a pro →
21 Gas Heating Lockout High ✗ Call a pro →
22 Abnormal Flame-Proving Signal High ✗ Call a pro →
23 Pressure Switch Did Not Open High ✗ Call a pro →
24 Secondary Voltage Fuse Is Open High ✗ Call a pro →
25 Model Selection or Setup Error Low ✗ Call a pro →
31 High-Heat Pressure Switch or Relay Did Not Close or Reopened High ✗ Call a pro →
32 Low-Heat Pressure Switch Did Not Close or Reopened High ✓ Yes →
33 Limit Circuit Fault High ✓ Yes →
34 Ignition Proving Failure High ✓ Yes →
41 Blower Motor Fault High ✗ Call a pro →
42 Inducer Motor Fault High ✗ Call a pro →
43 Low-Heat Pressure Switch Open While High-Heat Pressure Switch Is Closed High ✓ Yes →
45 Control Circuitry Lockout High ✗ Call a pro →

How to Read the Error Code

Carrier furnaces use a two-digit LED blink code on the control board. Count the short flashes (first digit) then the long flashes (second digit). A continuously off LED means no power to the control board; a continuously on LED indicates normal standby. Fault codes remain in memory and are automatically cleared after 72 hours.

About This Model

The Carrier 58MVP is a variable speed gas furnace using the Variable Speed Furnace Control control board.