Carrier 58MVP Error Code Code 32: Low Pressure Switch Fault
TL;DR
Indicates the low pressure switch (LPS) is closed at call for heat, or fails to close after call, or opens during operation. When the furnace control board flashes Fault Code 32, the unit shuts down, waits 2 minutes, stops flashing Fault Code 32, and restarts the heating cycle. Most likely cause: plugged condensate drain. Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk. What Does Code Code 32 Mean?
Indicates the low pressure switch (LPS) is closed at call for heat, or fails to close after call, or opens during operation. When the furnace control board flashes Fault Code 32, the unit shuts down, waits 2 minutes, stops flashing Fault Code 32, and restarts the heating cycle.
Common Causes
When to Call a Professional
Contact a licensed HVAC technician if:
- Basic troubleshooting did not resolve the error
- You smell gas at any point during the process
- You are not comfortable working around gas lines or electrical components
- The unit needs a gas valve, control board, or motor replacement