Carrier 58MVC Furnace Error Codes

Variable Speed Gas Furnace | Control Board: Variable Speed Furnace Control

Not your model? View all Carrier models →

Disclaimer
This information is for reference purposes only and does not guarantee accuracy or completeness. Always consult your owner's manual and a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

All Error Codes

Code Name Severity DIY?
Continuous OFF No Power / Control Failure High ✓ Yes
Continuous ON Normal Operation - No Call for Heat Info
Rapid Flashing Reversed Line Voltage Polarity High ✗ Call a pro
11 No Previous Code Info
12 Blower On After Power Up Info
13 Limit Circuit Lockout High ✓ Yes
14 Ignition Lockout High ✓ Yes
15 Blower Motor Lockout High ✗ Call a pro
21 Gas Heating Lockout High ✗ Call a pro
22 Abnormal Flame-Proving Signal High ✗ Call a pro
23 Pressure Switch Did Not Open High ✗ Call a pro
24 Secondary Voltage Fuse Is Open High ✗ Call a pro
25 Model Selection or Setup Error Low ✗ Call a pro
31 Medium-Heat Pressure Switch or HPSR Relay Did Not Close or Reopened High ✗ Call a pro
32 Low-Heat Pressure Switch Did Not Close or Reopened High ✓ Yes
33 Limit Circuit Fault High ✓ Yes
34 Ignition Proving Failure High ✓ Yes
41 Blower Motor Fault High ✗ Call a pro
42 Inducer Motor Fault High ✓ Yes
43 Low-Heat Pressure Switch Open While Medium-Heat Pressure Switch Is Closed High ✓ Yes
45 Control Circuitry Lockout High ✗ Call a pro

How to Read the Error Code

Carrier furnaces use a two-digit LED blink code on the control board. An amber LED flashes a short-then-long pattern: count the short flashes for the first digit, then the long flashes for the second digit. For example, three short flashes followed by four long flashes means code 34. The board stores recent fault codes for retrieval.

About This Model

The Carrier 58MVC is a variable speed gas furnace using the Variable Speed Furnace Control control board.