Amana AMVM970803BN Furnace Error Codes

Modulating, Variable Speed Gas Furnace | Control Board: Integrated Control Module

Not your model? View all Amana models →

Disclaimer
This information is for reference purposes only and does not guarantee accuracy or completeness. Always consult your owner's manual and a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

All Error Codes

Code Name Severity DIY?
None No Power to Control Module High ✓ Yes
d0 Equipment Lacks Shared Data High ✗ Call a pro
Eb0 Circulator Blower Motor Not Running High ✗ Call a pro
Eb1 Lost Communications with Circulator Blower Motor High ✗ Call a pro
Eb2 Circulator Blower Motor HP Mismatch High ✗ Call a pro
Eb3 Circulator Blower Motor Limiting Low ✓ Yes
Eb4 Circulator Blower Motor Loss of Rotor Control High ✓ Yes
Eb5 Circulator Blower Motor Failure High ✗ Call a pro
Eb7 Circulator Blower Motor Lacks Information High ✗ Call a pro
Eb9 Airflow Lower Than Demanded Low ✓ Yes
E10 Grounding Fault High ✗ Call a pro
E11 Open Rollout Switch High ✗ Call a pro
E15 Return Air Temperature Sensor Open (External) Low ✗ Call a pro
E16 Return Air Temperature Sensor Shorted (External) Low ✗ Call a pro
E17 Supply Air Temperature Sensor Open (External) Low ✗ Call a pro
E18 Supply Air Temperature Sensor Shorted (External) Low ✗ Call a pro
E19 Onboard Return Air Temperature Sensor Unplugged Low ✗ Call a pro
E1A Onboard Return Air Temperature Sensor Shorted Low ✗ Call a pro
Ed0 Data Not Yet on Network High ✗ Call a pro
Ed1 Invalid Shared Data High ✗ Call a pro
EE0 Ignition Lockout High ✓ Yes
EE1 Low Stage Pressure Switch Closed at Start High ✗ Call a pro
EE2 Low Stage Pressure Switch Not Closed High ✗ Call a pro
EE3 Primary Limit Circuit Open High ✓ Yes
EE4 Flame Sensed with No Call for Heat High ✗ Call a pro
EE5 Open Fuse / Low Voltage Short High ✗ Call a pro
EE6 Low Flame Sense Signal Low ✗ Call a pro
EE7 Igniter Circuit Fault High ✗ Call a pro
EE8 High Stage Pressure Switch Closed at Start Low ✗ Call a pro
EE9 High Stage Pressure Switch Not Closed Low ✗ Call a pro
EEA Reversed Polarity High ✗ Call a pro
EEb External Gas Valve Error High ✗ Call a pro
EEC Internal Gas Valve Error High ✗ Call a pro
EbF Inducer Communication Error High ✗ Call a pro
ECF Gas Valve Stepper Motor Communication Error High ✗ Call a pro

How to Read the Error Code

The integrated control module provides diagnostic information through a 7-segment LED display. The display will show an error code that may contain a letter and number. Furnace lockout results when a furnace is unable to achieve ignition after three attempts during a single call for heat, characterized by a non-functioning furnace and an EE0 code displayed on the 7-segment display. Accessing the furnace's diagnostic menu provides access to the last six faults detected. Any consecutively repeated fault is stored a maximum of three times.

About This Model

The Amana AMVM970803BN is a modulating, variable speed gas furnace using the Integrated Control Module control board.