Amana AMVM970803BN Error Code EE4: Flame Sensed with No Call for Heat

TL;DR
Your Amana AMVM970803BN is detecting flame when there should be none. Both blowers are running continuously as a safety measure. This is a safety concern — call a technician immediately.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code EE4 Mean?

Error code EE4 on the Amana AMVM970803BN indicates the flame sensor is detecting flame presence when the furnace has not called for heat and the gas valve should be closed. As a safety measure, the induced draft blower and circulator blower both run continuously to clear any combustion gases. The furnace will not initiate a new heating cycle until this condition is resolved.

This fault can be caused by a short to ground in the flame sensor rod or its wiring, which causes the control module to read a current signal even without a flame present. It can also be caused by a slow-closing gas valve that allows a residual flame to persist after the gas valve command goes to closed, or by a lingering or lazy burner flame that does not extinguish cleanly when the gas valve closes.

Because this fault involves a possible continuous gas leak through a slow-closing valve or an unexpected flame presence, it is a safety concern that requires immediate professional attention. A technician must correct any short at the flame sensor or in the flame sensor wiring, inspect for a lingering flame condition, and verify the gas valve is closing fully and promptly on command.

Common Causes

Cause Likelihood DIY?
Short to ground in flame sensor or wiring Most common ✗ Call a pro →
Slow-closing gas valve allowing lingering flame Common ✗ Call a pro →
Residual flame after gas valve closes Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You