Error Code EE8
Low

Amana AMVM970803BN Error Code EE8: High Stage Pressure Switch Closed at Start

TL;DR
Your Amana AMVM970803BN's high stage pressure switch is stuck closed. The furnace can still run on low stage but cannot operate on high stage. A technician must replace the switch or repair the wiring short.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code EE8 Mean?

Error code EE8 on the Amana AMVM970803BN means the high stage pressure switch circuit is already in the closed (activated) position at the start of a heating cycle, before the induced draft blower has operated at high speed. The furnace can still ignite and run on low stage, but it cannot transition to high-stage heating.

Under normal operation, the high stage pressure switch should be open at startup and only close when the inducer is operating at its high-speed setting and creating sufficient negative pressure for high-fire operation. Finding it pre-closed tells the control module that either the switch contacts are stuck in the closed position due to mechanical failure, or a short circuit in the high stage pressure switch wiring is creating a false closed signal.

A technician must determine whether the high stage pressure switch has mechanically failed in the closed position or whether the wiring circuit has a short. A stuck high-stage switch must be replaced with the correct replacement part. If the wiring has a short, the fault location must be found and the damaged section repaired. Because the furnace can still run on low stage, this fault does not stop all heating, but high-stage capacity is unavailable until repaired.

Common Causes

Cause Likelihood DIY?
High stage pressure switch contacts stuck closed Most common ✗ Call a pro →
Short in pressure switch circuit wiring Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Installation Instructions for *CVM97*B* & *MVM97*B* Modulating Gas Furnace

✓ Verified against manufacturer service manual — March 2026