This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code EEb Mean?

Error code EEb on the Amana AMVM970803BN indicates the control module has detected an external gas valve error. Specifically, the gas valve is either not energizing when the control module commands it to open, or it is remaining energized when the control module commands it to close. Either condition is a serious safety and operational concern, and the furnace shuts down as a result.

A gas valve that fails to open on command will prevent ignition, while a gas valve that fails to close on command could allow unburned gas to accumulate, creating a fire or explosion hazard. The EEb fault is specifically tied to the external valve wiring and connections — the manual directs checking the polarity, grounding, and wiring in the gas valve circuit, since reversed polarity or a poor ground can cause the valve to behave incorrectly.

A technician must verify the polarity of the 115VAC supply, check the unit ground connection, and inspect all wiring in the gas valve circuit for correct connection and continuity. If the wiring and electrical connections are correct and the valve still does not respond correctly to commands, the gas valve itself may need replacement.

Common Causes

Cause Likelihood DIY?
Gas valve not energizing when commanded Most common ✗ Call a pro →
Wiring issue in gas valve circuit Most common ✗ Call a pro →
Gas valve energizing when it should not be Common ✗ Call a pro →
Reversed polarity or poor ground Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Installation Instructions for *CVM97*B* & *MVM97*B* Modulating Gas Furnace

✓ Verified against manufacturer service manual — March 2026