Error Code Eb5
High

Amana AMVM970803BN Error Code Eb5: Circulator Blower Motor Failure

TL;DR
Your Amana AMVM970803BN's circulator blower motor has failed to start after 10 consecutive attempts, or has shut down due to a voltage or temperature problem. Professional service is required.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code Eb5 Mean?

Error code Eb5 on the Amana AMVM970803BN indicates the circulator blower motor has experienced a critical failure. The fault triggers under three conditions: the motor fails to start 10 consecutive times, the motor shuts itself down due to an over- or under-voltage condition, or the motor's power module reaches an over-temperature condition.

When the motor fails to start 10 times in a row, it typically means the motor wheel or shaft is mechanically obstructed and the motor cannot overcome the resistance to begin rotating. An over- or under-voltage shutdown means the incoming power supply voltage is outside the nameplate-specified range, causing the motor's internal protection circuitry to shut it down. An over-temperature condition on the power module indicates the motor is running too hot, often due to sustained high load from restricted airflow.

A technician must check the circulating blower for physical obstructions, verify the blower shaft rotates freely, inspect and repair or replace the blower motor or wheel as needed, and measure the voltage to the furnace to confirm it is within the nameplate-specified range.

Common Causes

Cause Likelihood DIY?
Blower motor obstructed or wheel jammed Most common ✗ Call a pro →
Blower motor failure after repeated start attempts Most common ✗ Call a pro →
Over or under voltage to furnace Common ✗ Call a pro →
Over temperature condition on power module Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes