Error Code E1A
Low

Amana AMVM970803BN Error Code E1A: Onboard Return Air Temperature Sensor Shorted

TL;DR
Your Amana AMVM970803BN's onboard return air temperature sensor has a short circuit. Try power cycling the furnace first. If the error persists, a technician must inspect the control board for foreign objects or damage near sensor R311.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code E1A Mean?

Error code E1A on the Amana AMVM970803BN indicates the onboard return air temperature sensor — component R311 on the control PCB — has a short circuit. This sensor is soldered directly onto the board, so the short is either within the component itself, caused by a foreign object on the PCB creating an unintended conductive path, or indicative of PCB damage. The onboard return air temperature will not appear in the CoolCloud App, but the furnace should continue to operate.

A short on the onboard sensor is more unusual than an open circuit fault, and the manual specifically identifies foreign objects on the PCB as a potential cause — dust, metallic debris, or conductive contamination bridging the sensor terminals can create a short-to-ground condition at R311. The initial troubleshooting step of power cycling allows up to 90 seconds for the control to re-scan its onboard sensors, which may clear a transient detection error.

If power cycling does not resolve E1A, a technician should open the furnace and carefully inspect the PCB surface around the R311 component for any foreign objects, metallic particles, moisture residue, or signs of PCB damage. If a foreign object is the cause, it can sometimes be carefully removed. However, if the component or the PCB traces are damaged, the PCB must be replaced.

Common Causes

Cause Likelihood DIY?
Onboard sensor component failure Most common ✗ Call a pro →
Foreign objects on PCB causing short at sensor R311 Common ✗ Call a pro →
Faulty PCB Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Installation Instructions for *CVM97*B* & *MVM97*B* Modulating Gas Furnace

✓ Verified against manufacturer service manual — March 2026