Code Name Severity DIY?
IF Internal Fault High ✗ Call a pro →
E0 Lockout High ✗ Call a pro →
E1 Low Stage Pressure Switch Stuck Closed High ✗ Call a pro →
E2 Low Stage Pressure Switch Stuck Open High ✗ Call a pro →
E3 Open High Limit Switch High ✓ Yes →
E4 Flame Detected When No Flame Should Be Present High ✗ Call a pro →
EC Inducer Motor Overcurrent Fault High ✗ Call a pro →
Ed Rollout Switch Open High ✗ Call a pro →
EF Auxiliary Input Open High ✗ Call a pro →
E5 Open Fuse High ✗ Call a pro →
E6 Low Flame Signal Low ✗ Call a pro →
E7 Igniter Fault High ✗ Call a pro →
E8 High Stage Pressure Switch Stuck Closed Low ✗ Call a pro →
E9 High Stage Pressure Switch Stuck Open Low ✗ Call a pro →
EA Reversed 115 VAC Polarity High ✗ Call a pro →
b0 Blower Motor Not Running High ✗ Call a pro →
b1 Blower Communication Error High ✗ Call a pro →
b2 Blower HP Mis-Match High ✗ Call a pro →
b3 Blower Motor Operating in Limit Condition Low ✓ Yes →
b4 Blower Motor Current Trip or Lost Rotor High ✓ Yes →
b5 Blower Motor Locked Rotor High ✗ Call a pro →
b6 Blower Over/Under Voltage Trip or Over Temperature Trip High ✗ Call a pro →
b7 Incomplete Parameters Sent to Motor High ✗ Call a pro →
b9 Low Indoor Airflow Low ✓ Yes →
d0 No Network Data High ✗ Call a pro →
d4 Invalid Memory Card Data Low ✗ Call a pro →

How to Read the Error Code

Refer to the Troubleshooting Codes for assistance in determining the source of unit operational problems. The dual 7-segment LED display will display an error code that may contain a letter and number. The error code may be used to assist in troubleshooting the unit. Furnace lockout results when a furnace is unable to achieve ignition after three attempts during a single call for heat. It is characterized by a non-functioning furnace and a E0 code displayed on the dual 7-segment display. Accessing the furnace's diagnostics menu provides ready access to the last ten faults detected by the furnace. Faults are stored most recent to least recent. Any consecutively repeated fault is stored a maximum of three times.