Error Code b6
High

Goodman GMVM970803BN Error Code b6: Blower Over/Under Voltage Trip or Over Temperature Trip

TL;DR
b6 means the ECM blower motor shut itself down due to abnormal voltage (too high or too low) or the motor power module overheating. A technician must diagnose the electrical supply and motor conditions.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code b6 Mean?

A b6 code on the Goodman GMVM970803BN indicates that the circulator blower motor has shut itself down due to either an abnormal voltage condition or an overheating condition in the motor's power module. The ECM motor has built-in self-protection that monitors incoming line voltage and internal temperatures, shutting down when either parameter exceeds safe limits. The furnace will not operate while this protection is active.

Voltage problems can originate from outside the furnace entirely. Utility power fluctuations, an undersized electrical circuit that sags under load, loose connections in the breaker panel or at the furnace disconnect, or other high-draw appliances on the same circuit can cause line voltage to drop below or spike above the acceptable operating range specified on the furnace rating plate (typically 115 VAC ±10%). Over-temperature conditions in the motor power module can occur if the blower compartment is in an excessively hot utility room, if there is insufficient clearance around the motor for heat dissipation, or if the motor is consistently working at high loads due to restricted airflow from a clogged filter or undersized ductwork.

A qualified HVAC technician or electrician should measure line voltage at the furnace while it is under load and verify it falls within the acceptable range. If voltage is within specification, the over-temperature protection may be triggering — the technician should check for airflow restrictions and ensure the motor has adequate ventilation space.

Common Causes

Cause Likelihood DIY?
High AC line voltage to furnace Common ✗ Call a pro →
Low AC line voltage to furnace Common ✗ Call a pro →
High ambient temperatures around blower motor Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.