Error Code E 406
High

Lennox SLP98UHV Error Code E 406: LSOM - Compressor Open Start Circuit

TL;DR
Your Lennox SLP98UHV has detected an open start circuit in the AC compressor. The compressor may have overheated, or the start winding has failed.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code E 406 Mean?

Error code E406 on the Lennox SLP98UHV indicates that the Lennox Smart Outdoor Monitor (LSOM) has detected an open start circuit in the compressor. The start circuit is responsible for getting the compressor motor spinning during startup, and an open circuit means current cannot flow through this winding.

The most common cause is a compressor that has overheated and tripped its internal thermal protector. When the compressor gets too hot — due to low refrigerant, dirty coils, a failed fan motor, or prolonged operation — the thermal protector opens the start circuit to prevent further damage. After the compressor cools down (which can take several hours), the protector may reset and allow the compressor to restart.

If the compressor does not restart after cooling, the start winding may have permanently failed. A technician should allow the compressor to cool completely, then check refrigerant pressures, verify the condenser fan is operating, and test the compressor motor windings. If the start winding is open with the compressor cool, the compressor needs replacement.

Common Causes

Cause Likelihood DIY?
Compressor overheated and internal thermal protector tripped Most common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Unit Information - SLP98UHV Series Units

✓ Verified against manufacturer service manual — March 2026