High

Lennox SLP98UHV Error Code E 348: No 24V Output Y2 to C

TL;DR
Your Lennox SLP98UHV's control board is not outputting 24V on the Y2 cooling signal, so second-stage cooling cannot activate. The relay on the board has likely failed.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code E 348 Mean?

Error code E348 on the Lennox SLP98UHV indicates that there is no 24-volt output between the Y2 and C terminals with a non-communicating outdoor unit. The Y2 relay (Stage 2 cooling relay) on the control board has failed — the relay contacts did not close or the relay coil did not energize.

The Y2 signal activates the second stage of cooling on two-stage air conditioners or heat pumps. Without this signal, the system is limited to first-stage cooling only (if Y1 is working). You may notice that the air conditioner runs but cannot keep up with cooling demand on hot days, because it cannot reach full capacity.

Like E347, this is an internal control board relay failure that requires board replacement. A technician should verify the fault by testing for 24V at the Y2 terminal during a second-stage cooling call, and replace the board if confirmed.

Common Causes

Cause Likelihood DIY?
Y2 relay on control board has failed Most common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Unit Information - SLP98UHV Series Units

✓ Verified against manufacturer service manual — March 2026