Error Code E 347
High

Lennox SLP98UHV Error Code E 347: No 24V Output Y1 to C

TL;DR
Your Lennox SLP98UHV's control board is not outputting 24V on the Y1 cooling signal, meaning your AC or heat pump's first stage cannot start. The relay on the board has likely failed.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code E 347 Mean?

Error code E347 on the Lennox SLP98UHV indicates that there is no 24-volt output between the Y1 and C terminals with a non-communicating outdoor unit. The Y1 relay (Stage 1 cooling relay) on the control board has failed — either the relay contacts did not close, or the relay coil did not energize when commanded.

The Y1 signal is what tells the outdoor air conditioner or heat pump to turn on for first-stage cooling. Without this signal, the outdoor unit will not start even though the thermostat is calling for cooling. The furnace blower may still run, but no cooling will occur.

This is an internal control board failure. The relay is a component soldered onto the board and cannot be individually replaced in the field. A technician will need to verify the fault by testing for 24V at the Y1 terminal and, if confirmed, replace the entire control board.

Common Causes

Cause Likelihood DIY?
Y1 relay on control board has failed Most common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Unit Information - SLP98UHV Series Units

✓ Verified against manufacturer service manual — March 2026