Error Code Eb6
High

Amana AMVC960803BN Error Code Eb6: Over/Under Voltage Trip or Over Temperature Trip

TL;DR
The ECM blower motor shut itself down due to a voltage problem (too high or too low) or because its power module overheated. An electrician should check your home's line voltage, and an HVAC technician should check the motor.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code Eb6 Mean?

Error code Eb6 on the Amana AMVC960803BN indicates that the ECM circulator blower motor's internal protection circuits have shut the motor down due to one of three conditions: line voltage that is too high, line voltage that is too low, or overheating of the motor's power module.

ECM motors operate within a specific voltage range. When the AC line voltage to the furnace exceeds approximately 140VAC or drops below approximately 70VAC, the motor's power electronics can be damaged and the motor will shut down to protect itself. Power quality problems in a home — such as a utility voltage surge, a shared circuit under heavy load, or a failing neutral connection — can push voltage outside this range. High ambient temperatures in the mechanical room, inadequate clearances around the furnace, or a defective motor power module can cause the module itself to overheat and trigger the over-temperature shutdown.

An electrician should measure the line voltage at the furnace disconnect and verify it is within the 108–132VAC normal range. An HVAC technician should assess the installation environment for ventilation issues and test the motor's condition. If the voltage and environment are normal and Eb6 persists, the ECM motor module may have failed.

Common Causes

Cause Likelihood DIY?
Line voltage too high (exceeds 140VAC) or too low (below 70VAC) Most common ✗ Call a pro →
High ambient temperature causing motor overheating Common ✗ Call a pro →
Motor power module over temperature Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Service Instructions - 34.5" Chassis ACVC96*BA/AMVC96*BA/GCVC96*BA/GMVC96*BA Gas Furnaces
  2. Amana AMVC960803BN Product Page

✓ Verified against manufacturer service manual — March 2026