Error Code E13
High

Amana AMVC960803BN Error Code E13: Redundant Relay Stuck Closed

TL;DR
The redundant gas valve relay on the control board is stuck closed, meaning gas flow cannot be safely shut off through normal control. Turn off the gas supply and call an HVAC technician immediately.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code E13 Mean?

Error code E13 on the Amana AMVC960803BN indicates that the redundant gas valve relay on the integrated control module is stuck in the closed (energized) position when it should be open. This is a critical safety fault because the redundant relay is part of the gas valve shutoff circuit — if it cannot open, the furnace loses an important layer of protection against uncontrolled gas flow.

The control module continuously monitors the state of both the primary and redundant gas valve relays. When the redundant relay cannot open — typically because the relay contacts have welded together from overcurrent, heat, or age — the control module detects the discrepancy and shuts down to prevent unsafe operation. The furnace will not operate in this state.

Because the stuck relay may allow the gas valve circuit to remain energized even when the furnace is commanded off, this condition warrants turning off the gas supply at the shutoff valve. The integrated control module must be replaced by a qualified HVAC technician. Do not attempt to reset or operate the furnace until after professional service has been completed.

Common Causes

Cause Likelihood DIY?
Redundant gas valve relay welded/stuck closed on control board Most common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.