Error Code EEC
High

Amana AMVC960803BN Error Code EEC: External Gas Valve Error

TL;DR
The gas valve is being energized when it should not be — this is a safety shutdown. Turn off the gas supply and call an HVAC technician immediately. Do not operate the furnace until the fault is corrected.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code EEC Mean?

Error code EEC on the Amana AMVC960803BN indicates an external gas valve error: the control module has detected that the gas valve circuit is energized when no ignition sequence is active. This is a serious safety condition and the furnace shuts down to prevent uncontrolled gas flow.

The most likely cause is miswired or shorted gas valve wiring that creates an unintended circuit path keeping the valve energized. A gas valve relay on the control board that is stuck in the closed (energized) position is another cause — in this case, the relay cannot open to de-energize the valve, meaning gas flow cannot be stopped through normal control. A shorted gas valve solenoid coil can also keep the circuit pathway active.

This fault indicates that the gas valve may be receiving power in an uncontrolled manner. Turn off the gas supply valve at the furnace and call an HVAC technician. Do not attempt to reset or operate the furnace until the gas valve circuit and control board relay have been inspected and confirmed safe.

Common Causes

Cause Likelihood DIY?
Miswired or shorted gas valve circuit Most common ✗ Call a pro →
Gas valve relay stuck closed on control board Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Service Instructions - 34.5" Chassis ACVC96*BA/AMVC96*BA/GCVC96*BA/GMVC96*BA Gas Furnaces
  2. Amana AMVC960803BN Product Page

✓ Verified against manufacturer service manual — March 2026